Hi Phil, I have now confirmed with the design team that the device will still be locked if only the JTAG signature 1 is written with 0x5555, but it is still best practice to use both. We are currently working on the next MSP-GANG release and we are including a fix for this so that it will match the user's guide recommendation. Regards, Katie
↧