Another way to phrase my question is to a TI engineer - is there any data on the typ variation of the ADC consumption at room temperature? Or in this case, is MAX in the datasheet not only at extremes of temperature? I have done some more testing and found that if I configure the MSP430 to capture at 200kSamples/second (i.e. ADC is on all the time - 4CLK sample + 13CLK conversion + syn) I find that the good device have 150uA for the ADC consumption (I measure average and then subtract Timer B only current). The worst device measure 200uA. I am trying to understand if this is in spec or if there is an issue with my design.
↧