Forum Post: RE: MSP430FR5847: Problem with switching MSP430FR5847 to 16 MHz clock

$
0
0
thanks! I'm new to FRAM chips... Shall I lock control register (FRCTL0_H = 0) after? PS maybe it is worth to add a small note in slau367l.pdf, under table 3-5 (CSCTL1 Register Description) that if you go with clock over 8MHz you have to set wait states, or at least check them?